A multiple use1 NiTi root canal file

Being able to rely on your tools in dental practice is priceless. It’s your choice: Why compromise between price and quality if you can have both? Discover VDW.ROTATE, as part of our selection of products, drawing on decades of clinical experience, materials science, testing evaluations and reliable manufacturing. VDW.ROTATE is the multiple use1 NiTi root canal file for continuous rotary preparation that can perform up to 8 cases.2

Why choose VDW.ROTATE?

Lower risk of file breakage

The combination of wire, design and dedicated heat treatment boosts the file’s resistance to cyclic fatigue and reduces the risk of file breakage without compromising cutting-efficiency.3

Short learning curve

The tactile feeling and the option to use VDW.ROTATE files in brushing or in pecking motion facilitate quick learning. 

Efficient debris removal

The adapted S cross section gives more space for debris removal and provides control of the instrument for a swift, thorough and safe preparation.3,4

Versatility

Intuitive 3-file basic sequence plus a wide range of larger files with matching paper points and gutta-percha for various clinical cases, including retreatments. Align to the specific clinical case by simply choosing between taper .04 or .06 and various ISO sizes.

Compose your own rotary file sequence

The basic 3-files sequence

Start with an intuitive 3-file basic sequence. Choose the taper according to canal anatomy.

  • Glide path file (grey): 15.04
  • Shaping file (yellow): 20.05
  • Shaping file (red): 25.06: for the majority of cases; 25.04 for narrow and highly curved canals incl. apical curvature
Instruments for larger canal anatomies

If the canal anatomy requires further shaping, use larger sizes after reaching working length. Mix and match sizes and tapers to create your own file sequence.

Available sizes: 30.04 / 35.04 / 40.04 / 50.04 / 60.04 / 30.06 / 35.06 / 40.06

A fine-tuned instrument for various clinical cases with the following features: 

Heat treatment boosting the flexibility without compromising cutting efficiency

Strengthens cyclic fatigue resistance of the file and lowers the risk of file breakage.3

Adapted S cross section for higher cutting efficiency

Gives more space for debris removal and provides control of the instrument for a swift and thorough preparation.3,4

Respects the natural canal anatomy

The instruments will follow the natural canal anatomy smoothly thanks to its specific heat treatment making the file more flexible.6

How to

Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
Step 6:
Step 7:
Step 8:
Step 9:
Step 10:
Step 11:
Step 12:
Step 13:
Step 14:
Step 15:

Related products

ProTaper Ultimate 
WaveOne Gold
TruNatomy

Frequently asked questions

For non-preset motors, please use the doctor’s choice mode. For simplicity reason, you can use the following 3 settings. All settings are safe to use.

  • VDW.ROTATE 15.04: 1.3 Torque [cNm]; 350 Speed [rpm]
  • VDW.ROTATE other shaping sizes: 2.0 Torque [cNm]; 350 Speed [rpm]
  • VDW.ROTATE Retreatment 25.05: 3.5 Torque [cNm]; 400 Speed [rpm]

VDW.ROTATE allows you to shape the canal with only 3 files for the majority of the cases: 1 glide path file and 2 shaping files. Therefore you save time compared to our 4-file Mtwo sequence. VDW.ROTATE also has a new file specific heat treatment, which makes the file more flexible without compromising its cutting efficiency.* Also, the adapted S cross section increases space for debris removal.** If you encounter narrow and highly curved canals, we also offer you a 25.04.

VDW.ROTATE files are reprocessable and reusable up to 8 times.1 For further information please consult our instructions for use, also available on the website.

 

VDW.ROTATE instruments have a constant taper, yet designed to respect the natural canal anatomy. Align to the specific clinical case by simply choosing between taper .06 or .04 and various ISO sizes. The instruments will follow the natural canal anatomy smoothly thanks to its specific heat treatment making the file more flexible.*

Workflows

Downloads

VDW.ROTATE | Brochure | EN
Endodontic instruments: Quality. Safety. Affordability.
1 MB

For instructions for use, safety data sheets, eMDR documents and more, visit our Download Center

Featured case study

Shaping a Type V mandibular premolar with VDW.ROTATE

Dr. Vittorio Franco graduated in dentistry in 1990 from the Sapienza University of Rome in Italy. He works in Rome and London in practices limited to endodontics. Read his case report on shaping a type V mandibular premolar with VDW.ROTATE.

What dentists say

“I really like that the VDW.ROTATE instruments are very flexible. I used them in highly curved canals and it was a pleasure to work them. Nevertheless they are very active and more resistant to breakage.”

Dr Paulina Piasta-Kiełkiewicz, Poland, Warsaw

“I really love working with VDW.ROTATE. It works very smoothly and the instrument design fits the user’s needs. In my opinion, it is an excellent solution for lovers of rotary motion.”

Dr Igor Šutić, Croatia, Zagreb

“I enjoy working with VDW.ROTATE, it is a system that allows me to deal with all kind of canals. The increased flexibility, the small taper .04 and the possibility to pre-curve the file, make it the right instrument to manage narrow and highly curved canals respecting the natural root canal anatomy.”

Dr Jose Francisco Gaviño Orduña, Spain, Barcelona

Contact us

1. Internal lab tests showing that VDW.ROTATE®' instruments having a tip size higher than ISO 025 were able to shape 8 Straight canals without fracture. Data on file. For more Information, contact Consumables-Data-Requests@dentsplysirona.com.

2. Internal lab tests showing that VDW.ROTATE® instruments having a tip size higher than

3. ISO 025 fulfilled the mechanical resistance criteria after 8 disinfection-sterilization cycles.  Data on file. For more Information, contact Consumables-Data-Requests@dentsplysirona.com.

4. Compared to other VDW continuous rotary instruments. Data on file. For more Information, contact Consumables-Data-Requests@dentsplysirona.com.

5. Compared to centered rotary cross section. Data on file. For more Information, contact Consumables-Data-Requests@dentsplysirona.com.

6. Lab tests showing a better performance of the VDW.ROTATE® instruments compared to the MTwo ones meaning higher flexibility. Data on file. For more Information, contact Consumables-Data-Requests@dentsplysirona.com.

7. Kanter V, Weldon E, Nair U, et al. A quantitative and qualitative analysis of ultrasonic versus sonic endodontic systems on canal cleanliness and obturation.Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011;112(6):809- 813.doi:10.1016/j.tripleo. 2011.06.002.