image-comparison grip-lines arrow-top-right zip arrow-right video minus arrow-back text shop twitter file home quick-order arrow-left youtube search arrow-down check all filter site_references image Slice 1 zoom 🎬 icons / _ icon size / _ download-queue Created with Sketch. chevron-down arrow-right picture pdf podcast exe plus hotline close xxx-1 burger clipboard linked-in ppt Artboard 🎬 icons / _ icon size / _ download-queue_add Created with Sketch. Layer 1 Created by potrace 1.15, written by Peter Selinger 2001-2017 My Account press_releases Created with Sketch. PRESS ds-instruments ds-preventive ds-implants ds-endodontics Cart presentation Created with Sketch. video Created with Sketch. other Created with Sketch. text_piece Created with Sketch. promotion Created with Sketch. Spare Parts ds-imaging-systems case_study Created with Sketch. ds-treatment-centers broschure Created with Sketch. ds-prosthetics ds-restorative video Created with Sketch. flyer Created with Sketch. whitepaper Created with Sketch. article Created with Sketch. image Created with Sketch. Service ds-cad-cam Quick Order Dentist Chair study Created with Sketch. ds-orthodontics ds-implants ds-endodontics ds-cerec digital-scan grinder ds-diagnosis step_1 analyse ds-abutment-placement more-quality initiative scan more-quality ds-polishing digital ds-irrigation ds-treatment-centers treatment ds-restorative ds-implant-planning realistic construct book ds-planning-impression mirror anwender ds-preventive planning-2 ds-obturation ds-cad-cam 04 ds-implant-placement ds-retention-protection ds-anesthetics restauration form ds-inlab oven robot plan place ds-orthodontics overlay ds-bone-regeneration ds-treatment-preparation vorher_nachher ds-maging-systems wifi omnicam treatment consulting planning comparison ds-set-up ds-prosthetics support step_3 ds-tooth-preparation ds-treatments ds-scaling step_2 ds-instruments software quote-english quote-french quote-text-german Created with Sketch. upload Created with Sketch. version Created with Sketch. globe
Dentsply Sirona France
Français
Accueil RETOUR
Accueil Produits Implantologie Astra Tech Implant system

Systèmes implantaires

Astra Tech Implant system

Harmonie entre la fonction, l'esthétique et la biologie

Dentist and patient

Résultats exceptionnels sur les niveaux de l'os marginal maintenus et les résultats cliniques à long terme

L'Astra Tech Implant System peut répondre à toutes les indications ; les résultats cliniques ont confirmé qu'il favorisait le maintien de l'os marginal**15.  

Lire nos conditions générales de garantie.

 

**15 Maintien de l'os marginal | Barewal RM, Stanford C, Weesner TC. A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability. Int J Oral Maxillofac Implants 2012;27(4):945-56.
De Bruyn H, Raes F, Cooper LF, et al. Three-years clinical outcome of immediate provisionalization of single Osseospeed() implants in extraction sockets and healed ridges. Clin Oral Implants Res 2013;24(2):217-23.
Galindo-Moreno P, Nilsson P, King P, et al. Clinical and radiographic evaluation of early loaded narrow diameter implants - 1-year follow-up. Clin Oral Implants Res 2012;23(5):609-16.
Gulje F, Abrahamsson I, Chen S, et al. Implants of 6 mm vs. 11 mm lengths in the posterior maxilla and mandible: A 1-year multicenter randomized controlled trial. Clin Oral Implants Res 2013;24(12):1325-31.
Noelken R, Donati M, Fiorellini J, et al. Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration. Clin Oral Implants Res 2014;25(1):3-9.
Noelken R, Neffe BA, Kunkel M, Wagner W. Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized Osseospeed implants placed into extraction sites: 2-year results. Clin Oral Implants Res 2014;25(2):214-20.
Palmer RM, Howe LC, Palmer PJ, Wilson R. A prospective clinical trial of single Astra Tech 4.0 or 5.0 diameter implants used to support two-unit cantilever bridges: results after 3 years. Clin Oral Implants Res 2012;23(1):35-40.
Sanz M, Cecchinato D, Ferrus J, et al. Implants placed in fresh extraction sockets in the maxilla: Clinical and radiographic outcomes from a 3-year follow-up examination. Clin Oral Implants Res 2014;25(3):321-7.
Stanford C, Barwacz C, Raes S. et al. Multicenter RCT comparing two related implant systems (P38). Academy of Osseointegration, March 12-14, San Francisco 2015.
Stanford CM, Barwacz C, Raes S, De Bruyn H, Cecchinato D, Bittner N, Brandt J. Multicenter clinical randomized controlled trial evaluation of an implant system designed for enhanced primary stability. Int J Oral Maxillofac Implants 2016;31(4):906-15.
Toia M, Galli S, Cecchinato D, Wennerberg A and Jimbo R. Clinical evidence of OsseoSpeed EV implants: a retrospective study and characterization of the newly introduced system. Accepted for publication 2015 May 1, Int J Periodont Rest Dent.


Caractéristiques clés

Astra Tech Implant system

Choix facile et utilisation simplifiée

L'Astra Tech Implant System est simple et fiable : un minimum de composants pour un maximum de flexibilité. Vous pouvez l'utiliser pour toutes les indications et les positions en bouche **16. Il est adapté pour la chirurgie en un et deux temps et est également adapté à la mise en charge immédiate et précoce **16. Les options de restauration comprennent les solutions scellées, transvissées et sur attachements.

 

Mise en place facile de l'implant

L'instrument de pose à code-couleur rend la pose des implants plus facile, rapide et efficace.

 

**16 Mode d’emploi - Astra Tech Implant System® Implants OsseoSpeed™

Astra Tech Implant system packages

Un minimum de composants avec un maximum de flexibilité : une connexion, trois tailles

Pour limiter le nombre de composants afin de simplifier la planification du traitement et la gestion des stocks, la connexion implant-pilier Conical Seal Design existe en trois dimensions : très étroite, étroite et large avec un code-couleur pour une identification facile.

Single Patient Drills

Forets à usage unique

Propriétés de coupe, manipulation simple et aucun nettoyage ni stérilisation. Tous les protocoles de forage peuvent bénéficier des avantages des forets à usage unique.

Color coded components

Empreinte au niveau de l'implant : composants avec code-couleur

Jaune, Océan et Lilas. Il n'a jamais été aussi simple de sélectionner les transferts d'implants Pick-up, les transferts, les vis guides et les répliques qui conviennent. Grâce au code-couleur, chaque composant est identifié par la couleur de la connexion d'implant sélectionnée.

Astra Tech Implant System BioManagement Complex

Astra Tech Implant System TX BioManagement Complex

Harmonie entre la fonction, l'esthétique et la biologie

La combinaison unique des caractéristiques indépendantes de l'Astra Tech Implant System BioManagement Complex garantit un résultat fiable, prédictible et esthétique à la fois sur le court et le long terme. **14

OsseoSpeed : accélération de la formation et de la cicatrisation osseuse**15

Surface en titane modifiée au Fluor avec une structure de surface unique à l'échellenanométrique pour une stimulation précoce de la cicatrisation osseuse et une accélération du processus de cicatrisation osseuse.

MicroThread : stimulation biomécanique de l'os**15

Micro-filetage sur le col de l'implant qui permet une distribution optimale des charges et réduit la valeur des contraintes.

Conical Seal Design : ajustage fort et stable

Connexion conique qui assure aussi un scellement hermétique de la partie interne de l’implant
par rapport aux tissus environnants réduisant ainsi considérablement les micro-mouvements et les micro-infiltrations.**17

Connective Contour : optimisation du volume et de la zone de contact des tissus mous

Contour créé par la connexion du pilier dans l’implant.

 

 

**14. Astra Tech Implant System BioManagement Complex™
Berglundh T, Abrahamsson I, Albouy JP, Lindhe J. Bone healing at implants with a fluoride-modified surface: an experimental study in dogs. Clin Oral
Implants Res 2007;18(2):147-52.
Bryington M, Mendonca G, Nares S, Cooper LF. Osteoblastic and cytokine gene expression of implant-adherent cells in humans. Clin Oral ImplantsRes 2014;25(1):52-8.
Donati M, La Scala V, Di Raimondo R, et al. Marginal Bone Preservation in Single-Tooth Replacement: A 5-Year Prospective Clinical Multicenter Study. Clin Implant Dent Relat Res 2013;E-pub July 25, doi:10.1111/cid.12117.
Ellingsen JE, Johansson CB, Wennerberg A, Holmén A. Improved retention and bone-to-implant contact with fluoride-modified titanium implants. Int J Oral Maxillofac Implants 2004;19(5):659-66.
Harder S, Dimaczek B, Acil Y, et al. Molecular leakage at implant-abutment connection--in vitro investigation of tightness of internal conical implantabutment connections against endotoxin penetration. Clin Oral Investig 2010;14(4):427-32.
Lee DW, Choi YS, Park KH, Kim CS, Moon IS. Effect of microthread on the maintenance of marginal bone level: a 3-year prospective study. Clin Oral Implants Res 2007;18(4):465-70.
Lops D, Chiapasco M, Rossi A, Bressan E, Romeo E. Incidence of inter-proximal papilla between a tooth and an adjacent immediate implant placed into a fresh extraction socket: 1-year prospective study. Clin Oral Implants Res 2008;19(11):1135-40.
Zipprich H, Weigl P, Lauer H-C, Lange B. Micro-movements at the implant-abutment interface: measurements, causes and consequenses. Implantologie 2007;15:31-45.

**15 Maintien de l'os marginal
Barewal RM, Stanford C, Weesner TC. A randomized controlled clinical trial comparing the effects of three loading protocols on dental implant stability. Int J Oral Maxillofac Implants 2012;27(4):945-56.
De Bruyn H, Raes F, Cooper LF, et al. Three-years clinical outcome of immediate provisionalization of single Osseospeed() implants in extraction sockets and healed ridges. Clin Oral Implants Res 2013;24(2):217-23.
Galindo-Moreno P, Nilsson P, King P, et al. Clinical and radiographic evaluation of early loaded narrow diameter implants - 1-year follow-up. Clin Oral Implants Res 2012;23(5):609-16.
Gulje F, Abrahamsson I, Chen S, et al. Implants of 6 mm vs. 11 mm lengths in the posterior maxilla and mandible: A 1-year multicenter randomized controlled trial. Clin Oral Implants Res 2013;24(12):1325-31.
Noelken R, Donati M, Fiorellini J, et al. Soft and hard tissue alterations around implants placed in an alveolar ridge with a sloped configuration. Clin Oral Implants Res 2014;25(1):3-9.
Noelken R, Neffe BA, Kunkel M, Wagner W. Maintenance of marginal bone support and soft tissue esthetics at immediately provisionalized Osseospeed implants placed into extraction sites: 2-year results. Clin Oral Implants Res 2014;25(2):214-20.
Palmer RM, Howe LC, Palmer PJ, Wilson R. A prospective clinical trial of single Astra Tech 4.0 or 5.0 diameter implants used to support two-unit cantilever bridges: results after 3 years. Clin Oral Implants Res 2012;23(1):35-40.
Sanz M, Cecchinato D, Ferrus J, et al. Implants placed in fresh extraction sockets in the maxilla: Clinical and radiographic outcomes from a 3-year follow-up examination. Clin Oral Implants Res 2014;25(3):321-7.
Stanford C, Barwacz C, Raes S. et al. Multicenter RCT comparing two related implant systems (P38). Academy of Osseointegration, March 12-14, San Francisco 2015.
Stanford CM, Barwacz C, Raes S, De Bruyn H, Cecchinato D, Bittner N, Brandt J. Multicenter clinical randomized controlled trial evaluation of an implant system designed for enhanced primary stability. Int J Oral Maxillofac Implants 2016;31(4):906-15.
Toia M, Galli S, Cecchinato D, Wennerberg A and Jimbo R. Clinical evidence of OsseoSpeed EV implants: a retrospective study and characterization of the newly introduced system. Accepted for publication 2015 May 1, Int J Periodont Rest Dent.

**16 Mode d’emploi - Astra Tech Implant System® Implants OsseoSpeed™

**17. Suivi à long terme
Cecchinato D, Bengazi F, Blasi G, et al. Bone level alterations at implants placed in the posterior segments of the dentition: outcome of submerged/ non-submerged healing. A 5-year multicenter, randomized, controlled clinical trial. Clin Oral Implants Res 2008;19(4):429-31.
Gotfredsen K. A 10-year prospective study of single tooth implants placed in the anterior maxilla. Clin Impl Dent Rel Res 2009;14(1):80-7.
Lops D, Bressan E, Chiapasco M, Rossi A, Romeo E. Zirconia and titanium implant abutments for single-tooth implant prostheses after 5 years of function in posterior regions. Int J Oral Maxillofac Implants 2013;28(1):281-7.
Mertens C, Steveling HG. Implant-supported fixed prostheses in the edentulous maxilla: 8-year prospective results. Clin Oral Implants Res 2010;22(5):464-72.
Mertens C, Steveling HG. Early and immediate loading of titanium implants with fluoride-modified surfaces: results of 5-year prospective study. Clin Oral Implants Res 2011;22(12):1354-60.
Palmer RM, Palmer PJ, Smith BJ. A 5-year prospective study of Astra single tooth implants. Clin Oral Implants Res 2000;11(2):179-82.
Schliephake H, Rodiger M, Phillips K, et al. Early loading of surface modified implants in the posterior mandible - 5 year results of an open prospective non-controlled study. J Clin Periodontol 2012;39 (2):188-95.
Wennström JL, Ekestubbe A, Gröndahl K, Karlsson S, Lindhe J. Implant-supported single-tooth restorations: a 5-year prospective study. J Clin Periodontol 2005;32(6):567-74.
Wennström JL, Ekestubbe A, Gröndahl K, Karlsson S, Lindhe J.Oral rehabilitation with implant-supported fixed partial dentures in periodontitis-susceptible subjects. A 5-year prospective study. J Clin Periodontol 2004;31(9):713-24.

Maintien de l'os marginal avec l'Astra Tech Implant System**15

Astra Tech Implant System, BioManagement Complex, unique en son genre, dont les résultats esthétiques et le maintien de l’os marginal sur le long terme sont avérés.

Les publications concluent que l'Astra Tech Implant System assure un niveau de maintien osseux encore supérieur à la norme actuelle décrivant les critères de réussite.**15


Chirurgie

L'Astra Tech Implant System offre aux professionnels dentaires des procédures simples qui assurent la réussite du traitement et de la restauration implantaires.

 

Interventions chirurgicales

Les implants OsseoSpeed TX ont été développés et largement documentés pour les interventions chirurgicales en un et en deux temps. Tous les implants de l'Astra Tech Implant System sont conçus pour permettre l'indexation. Le concept Conical Seal Design de l'Astra Tech Implant System permet une connexion implant-pilier solide et stable 

Procédure OsseoSpeed TX

Quels que soient la planification préopératoire et le protocole chirurgical choisi, le traitement par implants dentaires comprend une phase de préparation du site et une phase d'installation de l'implant. L'illustration ci-dessous décrit la préparation du site implantaire, conformément au protocole de forage standard pour l'installation des implants OsseoSpeed TX 4.5 et 4.0 S. Le forage doit être réalisé à une vitesse de 1 500 tours/minute, en irriguant abondamment.**16

 

**16 Mode d’emploi - Astra Tech Implant System® Implants OsseoSpeed™

 

site preparation : Ostéotomie (protocole de forage)
Implant installation : mise en place de l'implant
One-stage procedure : 1 temps chirurgical
two-stage procedure : 2 temps chirurgical
 

Procédure OsseoSpeed TX Profile

Les implants OsseoSpeed TX Profile requièrent des protocoles spécifiques pour la préparation du site, la mesure de l'ostéotomie et la mise en place de l'implant, en plus des procédures chirurgicales nécessaires pour les implants OsseoSpeed TX

L'illustration ci-dessous décrit la préparation d'un site implantaire, conformément au protocole de forage standard pour l'installation de l'implant OsseoSpeed TX Profile 5.0. **16

 

site preparation : Ostéotomie (protocole de forage)
Measuring : Contrôle
Implant installation : mise en place de l'implant
One-stage procedure : 1 temps chirurgical
two-stage procedure : 2 temps chirurgical

Implants

Les caractéristiques suivantes de nos implants dentaires font partie de l'Astra Tech Implant System BioManagement Complex :

  • OsseoSpeed : une surface implantaire avec une topographie nanométrique unique et modifiée par le fluor, qui stimule la formation osseuse précoce et renforce la liaison os/implant.
  • MicroThread : microfiletage sur le col de l'implant qui permet une distribution optimale des charges et réduit la valeur des contraintes.

L'apex conique de l'Astra Tech Implant System facilite l'installation de l'implant dans toutes les situations, mais particulièrement dans l'os de faible densité si un sous-forage est requis.

OsseoSpeed TX

La gamme complète d’implants OsseoSpeed TX couvre, notamment les cas présentant une hauteur osseuse verticale limitée, le remplacement des incisives latérales maxillaires et des incisives mandibulaires avec un espace horizontal limité, et les restaurations antérieures et postérieures.

Une connexion : trois dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X-Small 

3.0 S  Small   3.5 S 4.0 S Large   4.5 5.0 5.0 S

Pour une identification et une gestion simplifiées du stock, les étiquettes et composants disposent d'un code-couleur se rapportant à la taille de la connexion implant-pilier.

OsseoSpeed TX Profile 

OsseoSpeed TX Profile

L'OsseoSpeed TX Profile est un implant breveté de conception unique, développé spécialement pour les patients présentant une crête inclinée et qui vous permet de réussir un maintien osseux à 360° autour de l'implant, quel que soit l'emplacement dans la bouche.

 

Planification du traitement

Pour obtenir le résultat souhaité de votre traitement prothétique, il est impératif de développer des méthodes de planification de traitement en fonction de la morphologie des dents, de la fonction, de l'hygiène et de l'esthétique de chaque patient.

Dentsply Sirona Implants propose des outils vous permettant d'accéder aux informations importantes pour la planification du traitement implantaire optimal :

Simplant dental planning

Simplant : traitement d'implantologie guidée par ordinateur

Le logiciel de planification dentaire Simplant offre au clinicien des options chirurgicales précises et prédictibles. Il lui permet d'évaluer l'anatomie du patient et de vérifier si elle est adaptée à la restauration proposée.


En savoir plus sur Simplant

Radiographic implant guides

Guides radiographiques pour implants

Ces guides transparents peuvent s'utiliser pour superposer des contours d'implants sur des radiographies afin de vous aider à réaliser la mise en place de l'implant. Les guides sont spécifiques à l'implant et comportent différents agrandissements correspondant à l'agrandissement de la radiographie.

Remarque : certains produits ne sont pas disponibles sur tous les marchés. Contactez votre représentant Dentsply Sirona local pour obtenir des informations sur la gamme de produits actuelle et sa disponibilité.


Prothèse adjointe

L'Astra Tech Implant System offre toute une gamme de solutions prothétiques pour des résultats esthétiques et personnalisés. Que vous préfériez une construction prothétique scellée, transvissée ou sur attachements, ou que vous recherchiez des piliers préfabriqués ou personnalisés, nous avons une solution à vous proposer. 

Options scellées pour l'Astra Tech Implant System TX

Nous proposons des piliers préfabriqués et personnalisés. Toutefois, pour des résultats esthétiques aussi naturels que possible, nous recommandons l'utilisation des piliers Atlantis personnalisés.

Pilier Atlantis

Atlantis patient-specific abutments

Indication et utilisation

  • Édentements unitaires, partiels et totaux
  • Toutes les positions en bouche
Atlantis abutments

Caractéristiques

  • Simplification de la procédure de restauration
  • Évite la gestion des stocks de piliers
  • Le pilier Atlantis est conçu à partir de la forme finale de la dent

Avantages

  • Permet de gagner du temps que vous pourrez consacrer à votre patient.
  • Garantit une fonction et une esthétique optimisées

Direct Abutment

Atlantis direct abutments

Indication et utilisation

  • Restaurations unitaires, partielles ou totales
  • Toutes les positions en bouche
Atlantis abutment

Caractéristiques

  • API : tout-en-un dans un kit
  • Empreinte à clipper
  • Porte-pilier

Avantages

  • Optimisation de l'accès aux stocks et de leur contrôle
  • Empreinte rapide et fiable
  • Manipulation simplifiée

TiDesign

TiDesign edentulous

Indication et utilisation

  • Édentements unitaires, partiels ou totau
  • Toutes les positions en bouche
TiDesign Titanium

Caractéristiques

  • Marge prothétique festonnée, disponible en différents diamètres et hauteurs
  • Version angulée à 20°
  • TiDesign en titane 

Avantages

  • Moins de préparation, gain de temps
  • Davantage de possibilités de traitement
  • Matériau biocompatible et solide, adapté à toutes les positions en bouche

ZirDesign

ZirDesign edentulous

Indication et utilisation

  • Édentements unitaires et partiels
  • Dents antérieures, canines et prémolaires
ZirDesign Zirconia

Caractéristiques

  • Marge prothétique festonnée, disponible en différents diamètres et hauteurs
  • Version angulée à 20°
  • ZirDesign en zircone

Avantages

  • Moins de préparation, gain de temps et augmentation de la rentabilité
  • Davantage de possibilités de traitement
  • Matériaux biocompatible et solide pour des résultats esthétiques

CastDesign

CastDesign edentulous

Indication et utilisation

  • Édentements unitaires, partiels et totaux
  • Toutes les positions en bouche
  • Scellées : restaurations bridges et couronnes unitaires
  • Transvissées : restaurations couronnes unitaires uniquement
CastDesign

Caractéristiques

  • Base en alliage d'or avec cylindre en plastique
  • Compensation jusqu'à 30° d'angulation
  • Adapté aux restaurations scellées et transvissées

Avantages

  • Manipulation simplifiée pour le prothésiste dentaire
  • Fonction et esthétique même dans les cas complexes
  • Flexibilité clinique
  • Scellées : couronnes unitaires et bridges
  • Transvissées : couronnes unitaires uniquement

Options transvissées pour l'Astra Tech Implant System TX

UniAbutment

Pilier Uni Abutment

Indication et utilisation

  • Édentements partiels et totaux
  • Régions antérieure et postérieure
Conical Seal Design

Caractéristiques

  • Différentes hauteurs
  • Base conique auto-guidante de 11° (Conical Seal Design)
  • Conception différente du sommet du cône

Avantages

  • Gestion des tissus mous
  • Simple à manipuler
  • Offre de la flexibilité dans les situations cliniques où les implants ne sont pas parallèles
Atlantis single-tooth restoration

Atlantis

Indication et utilisation

  • Restaurations unitaires
  • Toutes les positions en bouche
Atlantis abutments

Caractéristiques

  • Simplification de la procédure de restauration
  • Évite la gestion des stocks de piliers
  • Le pilier Atlantis est conçu à partir de la forme finale de la dent

Avantages

  • Garantit une fonction et une esthétique
  • Permet de gagner du temps que vous pourrez consacrer à votre patient.
  • L'utilisation de métaux précieux n'est plus nécessaire
Angled Abutment

Angled Abutment

Indication et utilisation

  • Édentements partiels et totaux
  • Régions antérieure et postérieure
  • L' Angled Abutment est utilisé lorsqu'il est nécessaire de modifier le sens d'insertion de la vis de bridge par rapport à la direction axiale de l'implant
Two-piece component with angled top

Caractéristiques

  • Composant en deux pièces avec partie supérieure angulée
  • Angled Abutment, base conique auto-guidante de 11° (Conical Seal Design)
  • Angulation de 20°

Avantages

  • Permet une angulation de 20°
  • Simple à manipuler
  • Compensation du sens d'insertion de la vis de bridge

Options sur attachements pour Astra Tech Implant System TX

Découvrez ci-dessous les composants dont vous avez besoin pour un traitement de prothèse stabilisée associé à un traitement implantaire. La gamme vous permettra de répondre aux exigences fonctionnelles, esthétiques, phonétiques et hygiéniques de chaque patient.

Non-splinted restorations in the mandible

Pilier Locator

Indication et utilisation

  • Restaurations non solidarisées à la mandibule